Home ProductsSolar Surge Protection Device

DC lightning surge protection pv surge arrester 500v dc surge protection device

DC lightning surge protection pv surge arrester 500v dc surge protection device

    • DC lightning surge protection pv surge arrester 500v dc surge protection device
    • DC lightning surge protection pv surge arrester 500v dc surge protection device
  • DC lightning surge protection pv surge arrester 500v dc surge protection device

    Product Details:

    Place of Origin: CHINA
    Brand Name: THOR
    Certification: CE
    Model Number: TRS3-C40-500V 2P

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 piece
    Price: Negotiation
    Packaging Details: Carton packaging
    Delivery Time: 3-7 work day
    Payment Terms: L/C, T/T, Western Union, MoneyGram
    Supply Ability: 20000 pieces/month
    Contact Now
    Detailed Product Description
    Product Name: Surge Protective Device UC: 500V
    IN: 20KA IMAX: 40KA
    Standard: IEC/EN 61643-11 Certificate: CE
    Warranty: 2 Years OEM/ODM: YES

    Special purpose photovoltaic DC surge protector, overvoltage, current limiting and lightning protection circuit breaker.

     

    Product introduction


       Photovoltaic DC surge protector is a lightning protection product designed for the solar photovoltaic system based on the relevant standards. The lightning arrester adopts the multi-stage protection circuit, selects the brand components and makes use of the advanced production technology. It has the characteristics of large flow capacity, low residual pressure level, sensitive reaction, stable performance, reliable work and so on. It is suitable for the requirements of DC surge protection in photovoltaic power generation, wind power generation and other industrial fields.

     

     

     

    Working principle of product


        In the solar photovoltaic system, the inductive or capacitive coupling voltage is caused by the lightning shock and the switching operation of the upstream power supply system. Therefore, the surge may damage the photovoltaic modules and inverters, which will cause serious consequences for the operation of the photovoltaic system. The photovoltaic lightning arrester is specially developed for this purpose. The lightning protection module of the DC power supply, once the high voltage, and endanger the insulation of the protected equipment, the lightning arrester acts immediately, and the high voltage impact current is directed to the earth, thus limiting the amplitude of the voltage and protecting the insulation of the equipment. When the overvoltage is gone, the arrester is restored to its original state quickly, so as to protect the power equipment.

     

     


    Product features


      1. it can access multi-channel solar array at the same time. The maximum current per channel can reach 11A, which can meet different user needs.


      2. can be configured according to the needs of the sensor and monitoring and display module to measure and monitor the current of each road, and can record and display the operating conditions remotely, without the need for on-site selection;


      3. high quality flame retardant materials, fire insulation, rust prevention and safety.


      4. create the wiring connection to prevent incorrect contacts, and add a guarantee to your safety.

     

     

     

    Product specification

     
    Model RTS3-C40
    Rated Operating Voitage UC(V) 500 800 1000
    Voltage protective level Up(KV)≤ 1.8 3.0 3.6
    Max discharge current Imax(8/20μS) 40

    Nominal discharge current

     

    In(8/20μS) 20
    Ressponse time NS <25
    Lndication of invalidation Aging invalidation:green Normal,red:Invaldation
    Operating condition Temp:-40℃~+70℃
    RH≤95%(25℃)
    Sea level elevation≤3km

    Remote signal function

     

    Can also picking
    Remarks Other max continuous operating voltage can be customized
     

     


     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Use of attention


      1. standard RJ45 interface can be conveniently connected to the front end of the protected equipment. The grounding path should be as short as possible, and the length should not exceed 1.5 meters.


      2To avoid unnecessary induction loops, we should mark the PE conductor of each device.


      3. identify the input / output interface identifier of the lightning protector, input the external line and output the connection device.


      4. after correct installation, it can work steadily for a long time. If it is found that the transmission performance of the system is reduced or the signal is interrupted due to the cause of surge protection, it should be maintained or replaced in time.

     

     

     

    Company profile

     

       
       Zhejiang Thor Electric Co., Ltd is committed to meeting the requirements of the European Union’s Waste Electrical and Electronic Equipment (WEEE) directive. This directive requires producers of electrical and electronic equipment to finance the take-back for re-use or recycling of their products placed on the EU market after 2005.

     

     

     

     

    Product packaging:Carton packing

     

    Transportation method

    1. Express company: FEDEX,UPS,DHL,TNT

    2. Trains, ships, aircraft transport

     

    Contact Details
    Zhejiang THOR Electric Co., Ltd

    Contact Person: William

    Send your inquiry directly to us (0 / 3000)

    Other Products